Anke

How to Specify Chillers and Freezers for a UAE Kitchen

How to Specify Chillers and Freezers for a UAE Kitchen

Two quotes can describe the same fridge in two different ways. A clear specification makes them comparable.

To specify commercial chillers and freezers for a UAE kitchen, write ten lines for every unit: duty and temperature range, ambient rating, usable volume, footprint and clearance, body steel grade, refrigerant, defrost type, doors or drawers, power supply, and energy use per 24 hours. Then ask each supplier for a data sheet, a layout drawing and the warranty terms in writing.

A refrigeration specification is a short list of facts every unit must meet. It turns “2 door chiller” into something you can check, compare and approve for the back of house of a commercial kitchen. Counters on the shop floor follow the same logic, and display refrigeration adds the remote or plug-in choice. Consultants, fit-out contractors and owners use it to get like-for-like quotes for a commercial refrigeration range.

Key takeaways

  • “Stainless steel chiller” is not a specification. Grade, range and rating are.
  • Ambient rating matters most in hot UAE kitchens, and it can differ across one maker’s range.
  • A dial setpoint is not proof of safe food. The food temperature is.
  • This guide covers what to write once sizes are known. Sizing is a separate step.

What does a refrigeration specification include?

A specification has one row per unit and the same columns for every row: unit type and location, performance, build, and services. When every supplier fills the same columns, you compare facts, not adjectives.

What are the 10 lines every chiller and freezer spec needs?

1. Duty and temperature range

State chiller or freezer and the cabinet range. The Dubai Food Code asks for chilled high-risk food at or below 5°C and frozen food at -18°C. Some current Dubai guides quote 4°C for chilled food, so ask your inspector which edition applies and specify a range that sits comfortably below the limit.

2. Ambient rating

The ambient rating is the hottest room the unit is designed to work in while holding its stated temperature. Makers group it into climate classes, and the hottest class suits kitchens that stay at 40°C and above. In ANKE’s catalogue, uprights, under counters and bottle coolers are rated for 43°C, while prep chillers, saladettes and blast freezers are rated for 32°C. Check every product line, not just the brand. Then ask to see the unit hold temperature at the hottest hour of the day.

3. Usable volume

Write litres and the GN pan or tray size it must hold. Ask for usable litres, not gross litres. To work out how much you need, see how much refrigeration a restaurant kitchen needs.

4. Footprint and clearance

Give width, depth and height in millimetres, plus door swing and the ventilation gap. Every compressor needs fresh air in and hot air out.

5. Body material

Write the grade, not just “stainless”. Grade 304 is the usual choice for kitchen refrigeration; see 304 vs 316 vs 201 stainless steel.

6. Refrigerant

Ask which gas the unit uses and how much it holds. Many modern units use natural R290; some blast freezers use other refrigerants.

7. Defrost type

Ask how the unit defrosts: off-cycle, electric or hot gas. Defrost changes temperature swings, energy use and how often staff must clean the coil.

8. Doors, drawers and shelves

Solid or glass doors, drawers for the line, and the number of shelves or tray slides.

9. Power supply

Confirm voltage, plug type, electrical load and whether the unit needs a dedicated socket.

10. Energy use per 24 hours

Ask for kWh per 24 hours from the data sheet, so you can compare running costs.

What does a finished schedule look like?

Here are three rows written from ANKE’s catalogue data.

Unit Range Ambient Volume Steel / gas
Upright chiller, 2 doors -2 to +10°C 43°C 1,017 L 304 / R290
Under counter freezer, 2 doors -18 to -22°C 43°C 169.8 L 304 / R290
Blast freezer, 5 trays +3 to -40°C 32°C 90 L 304 / per data sheet

Notice the blast freezer row. Its ambient rating is lower, so it belongs in a ventilated, cooler spot, not beside the fryers.

Want your equipment list turned into a schedule? Send it and ANKE will return the range, ambient rating, volume and steel grade for every unit. Send your equipment list

Which documents should you ask for before ordering?

  • Data sheet for each unit
  • Layout drawing with clearances
  • Power load list
  • Warranty terms in writing
  • Delivery and installation scope, including commissioning
  • Service response time and spare parts, in writing

The last line matters more than most buyers expect. In a review of 75 one-to-three-star Google reviews of 16 UAE kitchen equipment suppliers, carried out for ANKE in October 2026, after-sales failure was the top complaint (24 mentions), followed by slow or no response (18). If a supplier cannot send a data sheet or a service promise, treat the quote as incomplete.

Which mistakes make quotes impossible to compare?

  • Writing “stainless steel” without a grade
  • Leaving out the ambient rating
  • Comparing gross litres with usable litres
  • Ignoring the ventilation gap in the layout
  • Skipping energy use per 24 hours

Fix these five, and most quotes line up on one page.

Our view: the ambient rating matters more than the logo

A well-known brand rated for a cool store room can still struggle beside a UAE hot line. Match the rating to the room first. Then compare brands.

How ANKE helps you specify refrigeration

ANKE International manufactures commercial chillers and freezers in Ajman and has served kitchens since 1997, for brands such as Tim Hortons, Caribou Coffee and L’ETO Cafe, across the UAE, Saudi Arabia, Oman, Qatar, Bahrain and India. Every unit is built in 304 stainless steel and carries a 1-year warranty.

Explore the chillers and freezers made in Ajman, including the under counter chiller, lowboy chiller, preparation chiller and bottle cooler. Front-of-house counters are on the display counters page. Your next step: add an ambient rating column to your equipment list today.

Writing a refrigeration spec for a UAE project?

Send your equipment list and ANKE will return a schedule with every line filled in.

Request a refrigeration schedule

Prefer WhatsApp? Message ANKE on +971 50 335 6748.

Frequently asked questions

What temperature should a commercial chiller hold in Dubai?

The Dubai Food Code asks for chilled high-risk food at or below 5°C and frozen food at -18°C. Check the food with a probe thermometer, because the dial setting alone does not prove the food is safe.

What does ambient rating mean on a fridge?

It is the highest room temperature at which the unit is designed to hold its stated cabinet temperature. A hot kitchen needs a higher rating than an air-conditioned store room.

Is R290 refrigerant safe for kitchens?

R290 is a natural refrigerant (propane) used in sealed commercial units built to safety standards. Trained technicians should install and service it.

Do I need a blast freezer as well as freezers?

If you cook in batches and store food for later, yes. A blast freezer cools cooked food quickly; a storage freezer only keeps frozen food frozen.

UAE

ANKE
105 Amr Ibn El Aas St Ajman
Industrial 1 - Ajman

+971 6748 0178
Saudi Arabia

ANKE
Riyadh

+966 55 490 7756
India
ANKE International

Athipalayam Road
Chinnavedampatti
Coimbatore

+91 422 439 2838
info@ankeintl.com
www.ankeintl.com

© Copyright 2026 ANKE. All rights reserved.